Noninvasive cross-sectional imaging of proximal caries using swept-source optical coherence tomography (SS-OCT) in vivo.

Noninvasive cross-sectional imaging of proximal caries using swept-source optical coherence tomography (SS-OCT) in vivo. J Biophotonics. 2013 Mar 1; Authors: Shimada Y, Nakagawa H, Sadr A, Wada I, Nakajima M, Nikaido T, Otsuki M, Tagami J, Sumi Y Abstract The aim of this study was to determine the diagnostic accuracy of swept-source optical coherent tomography …

Continue reading »

Feb 03 2013

Mineral density, morphology and bond strength of natural versus artificial caries-affected dentin.

Related Articles Mineral density, morphology and bond strength of natural versus artificial caries-affected dentin. Dent Mater J. 2013;32(1):138-143 Authors: Joves GJ, Inoue G, Nakashima S, Sadr A, Nikaido T, Tagami J Abstract This study aimed to investigate an artificial caries-affected dentin (ACAD) model for in vitro bonding studies in comparison to natural caries-affected dentin (NCAD) …

Continue reading »

Feb 03 2013

Resistance of dentin coating materials against abrasion by toothbrush.

Related Articles Resistance of dentin coating materials against abrasion by toothbrush. Dent Mater J. 2013;32(1):68-74 Authors: Gando I, Ariyoshi M, Ikeda M, Sadr A, Nikaido T, Tagami J Abstract Thin-film coating of root dentin surface by all-in-one adhesives has been shown to be an effective option to prevent root surface caries. The purpose of this …

Continue reading »

Jan 30 2013

Effects of solvent drying time and water storage on ultimate tensile strength of adhesives.

Related Articles Effects of solvent drying time and water storage on ultimate tensile strength of adhesives. J Investig Clin Dent. 2013 Jan 25; Authors: Emamieh S, Sadr A, Ghasemi A, Torabzadeh H, Akhavanzanjani V, Tagami J Abstract AIM: Simplified adhesives are a blend of monomers with solvents that are expected to evaporate before light curing. …

Continue reading »

Nov 29 2012

Non-destructive characterization of voids in six flowable composites using swept-source optical coherence tomography.

Related Articles Non-destructive characterization of voids in six flowable composites using swept-source optical coherence tomography. Dent Mater. 2012 Nov 23; Authors: Nazari A, Sadr A, Saghiri MA, Campillo-Funollet M, Hamba H, Shimada Y, Tagami J, Sumi Y Abstract OBJECTIVE: The aim of this study was to evaluate the void frequency (V(F)) and void volume (V(V)) …

Continue reading »

Nov 21 2012

In vitro evaluation of dentinal hydraulic conductance and tubule sealing by a novel calcium-phosphate desensitizer.

Related Articles In vitro evaluation of dentinal hydraulic conductance and tubule sealing by a novel calcium-phosphate desensitizer. J Biomed Mater Res B Appl Biomater. 2012 Nov 19; Authors: Thanatvarakorn O, Nakashima S, Sadr A, Prasansuttiporn T, Ikeda M, Tagami J Abstract In the current trend of materials used for dentin hypersensitivity treatment, calcium-phosphate-containing desensitizers are …

Continue reading »

Oct 23 2012

Validation of swept source optical coherence tomography (SS-OCT) for the diagnosis of smooth surface caries in vitro.

Related Articles Validation of swept source optical coherence tomography (SS-OCT) for the diagnosis of smooth surface caries in vitro. J Dent. 2012 Oct 16; Authors: Nakagawa H, Sadr A, Shimada Y, Tagami J, Sumi Y Abstract OBJECTIVE: An accurate evaluation of the extent of dental caries and possible progress of the lesion from enamel into …

Continue reading »

Older posts «

» Newer posts